+86 15603721115 tyler@lnashp.com

Maanshan Leomon Energy-Saving Technology Co. LTD
  • Home
  • About us
  • Products
    • Air Source Heat Pumps
      • Domestic Heat Pumps
      • Commercial Heat Pumps
      • Industrial Heat Pumps
    • Heat Pump Cylinders
    • Air to Water Heat Pumps
    • Swimming Pool Heat Pump
      • Residential Swimming Pool Heat Pump
      • Commercial Swimming Pool Heat Pump
      • Spa Heat Pump
    • Hot Water Heat Pumps
      • Domestic Hot Water Heat Pumps
      • Commercial Hot Water Heat Pumps
    • Underfloor Heating Heat Pumps
    • High Temperature Heat Pumps
    • Cold Climate Heat Pumps
      • Low Temperature Heat Pumps
      • EVI Heat Pumps
    • Geothermal Heat Pump
      • Ground Source Heat Pump
    • DC Inverter Heat Pumps
    • CO2 Heat Pumps
  • News
    • Company news
      • new projects of heat pumps
      • patent of heat pumps
    • Industry-news
  • Contact us

Industry-news

  1. Home
  2. News
  3. Industry-news
  4. The principle and difference of direct h...

The principle and difference of direct heating and circulating heating of hot water heat pump

There are two heating methods for air source hot water heat pumps: direct heating and circulating. Both methods are healthy and effective heating methods. But they are slightly different. The following Leomon Technology introduces you to the principle and difference between direct heating and circulating heating of air source hot water heat pumps.

Direct heating hot water heat pump:
The tap water is directly connected to the cold water inlet of the hot water heat pump unit, and the cold water flow is adjusted through the operation of the host and the circuit control program, so that the cold water entering the condenser of the host is heated to the set water temperature at one time (default 55 degrees can be freely Adjust), and then enter the hot water storage tank for storage. The host keeps working continuously and stops when the water level in the hot water storage tank reaches the set water level.

Circulating hot water heat pump:
The tap water is first replenished into the hot water storage tank by the water level control of the host. When the water level is higher than the minimum heating level of the hot water heat pump, the heat pump unit will start and continue to replenish cold water to the water tank. It will stop when the water level is full. The cold water in the water tank passes through the circulating water pump Operation, continuously circulates between the water tank and the host, slowly heating up, and continuously working, so that the heat pump stops working when the water temperature in the water tank reaches the set temperature.

The direct heating and circulating heating of air source hot water heat pumps are suitable for heat pumps without volume. Generally 270L uses direct heating. It is more energy-efficient to use circulatory heating above 270L. Leomon Technology is a professional manufacturer of air source hot water heat pumps. If you need to equip your home, company or swimming pool with hot water heat pumps. Welcome to consult. We will provide you with free budget services.


Related News

Types of Geothermal Heat Pump Systems

Types of Geothermal Heat Pump Systems

At What Temperature does a Pool Heat Pump Work

At What Temperature does a Pool Heat Pump Work

The development history of air source hot water heat pumps

The development history of air source hot water heat pumps

More and more young people choose residential swimming pool heat pump

More and more young people choose residential swimming pool

Swimming Pool Heat Pump HS Code

Swimming Pool Heat Pump HS Code

How does the cooling and heating air source heat pump realize the cooling and heating functions?

How does the cooling and heating air source heat pump realiz

Product Categories

  • Air Source Heat Pumps
    • Domestic Heat Pumps
    • Commercial Heat Pumps
    • Industrial Heat Pumps
  • Heat Pump Cylinders
  • Air to Water Heat Pumps
  • Swimming Pool Heat Pump
    • Residential Swimming Pool Heat Pump
    • Commercial Swimming Pool Heat Pump
    • Spa Heat Pump
  • Hot Water Heat Pumps
    • Domestic Hot Water Heat Pumps
    • Commercial Hot Water Heat Pumps
  • Underfloor Heating Heat Pumps
  • High Temperature Heat Pumps
  • Cold Climate Heat Pumps
    • Low Temperature Heat Pumps
    • EVI Heat Pumps
  • Geothermal Heat Pump
    • Ground Source Heat Pump
  • DC Inverter Heat Pumps
  • CO2 Heat Pumps

Latest Post

  • Swimming Pool Heat Pump Sizing Chart
    Swimming Pool Heat Pump Sizing Chart
    2023-05-27
  • Air Source Heat Pump are They Noisy
    Air Source Heat Pump are They Noisy
    2023-05-20
  • Heat Pump Fan Speed Adjustment
    Heat Pump Fan Speed Adjustment
    2023-05-13
  • +86 15603721115

    +86 15603721115

    tyler@lnashp.com

    Cihu Technical Area, Maanshan. China

    LatestPost

    • Swimming Pool Heat Pump Sizing Chart
      Swimming Pool Heat Pump Sizing Chart
      2023-05-27
    • Air Source Heat Pump are They Noisy
      Air Source Heat Pump are They Noisy
      2023-05-20
    • Heat Pump Fan Speed Adjustment
      Heat Pump Fan Speed Adjustment
      2023-05-13

    Feedback

    Contact Us

    +86 15603721115

    +86 15603721115

    tyler@lnashp.com

    Cihu Technical Area, Maanshan. China

    MOBILE WEBSITE

    Copyright © 2016 Maanshan Leomon Energy-Saving Technology Co. LTD All Rights Reserved.

    • Skype.
    • E-mail
    • Whatsapp
    • Inquiry
    Inquiry Us Now !
    Inquiry Us Now !