+86 15603721115 tyler@lnashp.com

Maanshan Leomon Energy-Saving Technology Co. LTD
  • Home
  • About us
  • Products
    • Air Source Heat Pumps
      • Domestic Heat Pumps
      • Commercial Heat Pumps
      • Industrial Heat Pumps
    • Heat Pump Cylinders
    • Air to Water Heat Pumps
    • Swimming Pool Heat Pump
      • Residential Swimming Pool Heat Pump
      • Commercial Swimming Pool Heat Pump
      • Spa Heat Pump
    • Hot Water Heat Pumps
      • Domestic Hot Water Heat Pumps
      • Commercial Hot Water Heat Pumps
    • Underfloor Heating Heat Pumps
    • High Temperature Heat Pumps
    • Cold Climate Heat Pumps
      • Low Temperature Heat Pumps
      • EVI Heat Pumps
    • Geothermal Heat Pump
      • Ground Source Heat Pump
    • DC Inverter Heat Pumps
    • CO2 Heat Pumps
  • News
    • Company news
      • new projects of heat pumps
      • patent of heat pumps
    • Industry-news
  • Projects
    • Heat Pumps for School Underfloor Heating Renovation Project
    • Heat Pumps for Hospital for Heating and Hot Water
    • Radiant Floor Heating and Cooling with Air Source Heat Pump
    • Air Conditioner Floor Heating and Hot Water in One Heat Pump for a 200 Square House
    • Heating and Cooling Heat Pumps for Swimming Pool
  • Blog
    • What Is a Heat Pump and How Does It Work?
    • Heat Pumps vs Air Conditioners
    • Do Air Source Heat Pumps Work in Cold Weather?
    • Air Source Heat Pump and Underfloor Heating
    • How to Choose a Pool Heater: Gas Heater, Heat Pump or Solar Heater?
    • How to choose Floor Heating Heat Pumps
    • Are heat pump water heaters worth the cost?
    • Heat Pump Water Heater vs Electric Water Heater
    • Advantages of Heat Pumps
    • Disadvantages of Heat Pumps
  • Contact us

Industry-news

  1. Home
  2. News
  3. Industry-news
  4. The principle and difference of direct h...

The principle and difference of direct heating and circulating heating of hot water heat pump

There are two heating methods for air source hot water heat pumps: direct heating and circulating. Both methods are healthy and effective heating methods. But they are slightly different. The following Leomon Technology introduces you to the principle and difference between direct heating and circulating heating of air source hot water heat pumps.

Direct heating hot water heat pump:
The tap water is directly connected to the cold water inlet of the hot water heat pump unit, and the cold water flow is adjusted through the operation of the host and the circuit control program, so that the cold water entering the condenser of the host is heated to the set water temperature at one time (default 55 degrees can be freely Adjust), and then enter the hot water storage tank for storage. The host keeps working continuously and stops when the water level in the hot water storage tank reaches the set water level.

Circulating hot water heat pump:
The tap water is first replenished into the hot water storage tank by the water level control of the host. When the water level is higher than the minimum heating level of the hot water heat pump, the heat pump unit will start and continue to replenish cold water to the water tank. It will stop when the water level is full. The cold water in the water tank passes through the circulating water pump Operation, continuously circulates between the water tank and the host, slowly heating up, and continuously working, so that the heat pump stops working when the water temperature in the water tank reaches the set temperature.

The direct heating and circulating heating of air source hot water heat pumps are suitable for heat pumps without volume. Generally 270L uses direct heating. It is more energy-efficient to use circulatory heating above 270L. Leomon Technology is a professional manufacturer of air source hot water heat pumps. If you need to equip your home, company or swimming pool with hot water heat pumps. Welcome to consult. We will provide you with free budget services.


Related News

Inverter VS Heat Pump

Inverter VS Heat Pump

Air Source Heat Pump Customer Reviews

Air Source Heat Pump Customer Reviews

Inverter Heat Pumps for Pools

Inverter Heat Pumps for Pools

8 common problems in the installation of air source heat pumps

8 common problems in the installation of air source heat pum

Precautions for purchasing heat pump water heaters

Precautions for purchasing heat pump water heaters

What are the features of heat pump swimming pool heaters?

What are the features of heat pump swimming pool heaters?

Product Categories

  • Air Source Heat Pumps
    • Domestic Heat Pumps
    • Commercial Heat Pumps
    • Industrial Heat Pumps
  • Heat Pump Cylinders
  • Air to Water Heat Pumps
  • Swimming Pool Heat Pump
    • Residential Swimming Pool Heat Pump
    • Commercial Swimming Pool Heat Pump
    • Spa Heat Pump
  • Hot Water Heat Pumps
    • Domestic Hot Water Heat Pumps
    • Commercial Hot Water Heat Pumps
  • Underfloor Heating Heat Pumps
  • High Temperature Heat Pumps
  • Cold Climate Heat Pumps
    • Low Temperature Heat Pumps
    • EVI Heat Pumps
  • Geothermal Heat Pump
    • Ground Source Heat Pump
  • DC Inverter Heat Pumps
  • CO2 Heat Pumps

Links

Latest Post

  • CO2 Heat Pump Disadvantages
    CO2 Heat Pump Disadvantages
    2023-01-28
  • Cold Climate Heat Pump vs Geothermal
    Cold Climate Heat Pump vs Geothermal
    2023-01-21
  • Inverter Pool Heat Pump APP
    Inverter Pool Heat Pump APP
    2023-01-14
  • LatestPost

    • CO2 Heat Pump Disadvantages
      CO2 Heat Pump Disadvantages
      2023-01-28
    • Cold Climate Heat Pump vs Geothermal
      Cold Climate Heat Pump vs Geothermal
      2023-01-21
    • Inverter Pool Heat Pump APP
      Inverter Pool Heat Pump APP
      2023-01-14

    Feedback

    Contact Us

    +86 15603721115

    +86 15603721115

    tyler@lnashp.com

    Cihu Technical Area, Maanshan. China

    MOBILE WEBSITE

    Copyright © 2016 Maanshan Leomon Energy-Saving Technology Co. LTD All Rights Reserved.

    • Skype.
    • E-mail
    • Whatsapp
    • Inquiry
    Inquiry Us Now !
    Inquiry Us Now !