+86 15603721115 tyler@lnashp.com

Leomon
  • Home
  • About us
  • Products
    • High Temperature Heat Pumps
    • Air Source Heat Pumps
      • Domestic Heat Pumps
      • Commercial Heat Pumps
      • Industrial Heat Pumps
    • Swimming Pool Heat Pump
      • Residential Swimming Pool Heat Pump
      • Commercial Swimming Pool Heat Pump
      • Spa Heat Pump
    • Hot Water Heat Pumps
      • Domestic Hot Water Heat Pumps
      • Commercial Hot Water Heat Pumps
    • Cold Climate Heat Pumps
      • Low Temperature Heat Pumps
      • EVI Heat Pumps
    • Air to Water Heat Pumps
    • Geothermal Heat Pump
      • Ground Source Heat Pump
    • DC Inverter Heat Pumps
    • Underfloor Heating Heat Pumps
    • Heat Pump Cylinders
    • CO2 Heat Pumps
      • R744 Heat Pumps
  • News
  • Contact us
  1. Home
  2. Products
  3. Air Source Heat Pumps
  4. Industrial Heat Pumps
  5. 60kW Air Source Heat Pump
  • 60kW Air Source Heat Pump

60kW Air Source Heat Pump

  • Product Item:Air Source Heat pump
  • Max. COP: 5.56
  • Compressor : DC Inverter Compressor
  • Running Temp: -15℃~45℃
  • Function : Water Heating & Cooling
  • Inquiry Send Email

    Description


    Air source heat pumps are capable of satisfying heat loads ranging from 17kW to 45kW with a single unit, and can achieve outputs up to 630kW when combined. Efficient design provides excellent seasonal performance, helps meet building codes and reduces operating costs.


    Features:

    1. High efficiency and high output air source heat pump with electronic expansion valve. Designed for outdoor installations.

    2. Two scroll compressors flexibly and efficiently adapt to fluctuating heat demands and intelligently load switch between compressors to maximize compressor life.

    3. Supplied with complete wall mounted heat pump manager.

    4. Reduced operating noise by using two slow-running EC-3D fans, a hermetically sealed compressor housing, and a free-swinging compressor base plate.


    Technical Specifications:

    Colour/Finish/Material White aluminium (similar to RAL 9006)

    Heat Output (kW) 50.0kW @ A2/W35

    Heat Pump CoP 3.70

    Installation Outdoor - The LA TU series uses three-phase power, making it suitable for a range of non-domestic/commercial applications with heat load requirements up to 60kW. If desired, multiple heat pumps can be installed in parallel.

    Noise level (Sound pressure level dB(A) at 10m): 50.00

    Noise level (Sound pressure level dB(A) at 1m): 74.00

    Outside air temperature range (oC): -25 / +35


    Aspect

    Height (mm): 2300.00

    Depth (mm): 1000.00

    Width (mm): 1900.00

    Weight (kg): 915.00


    Certification

    Chief Executive: yes


    Additional features

    Defrost: automatic - reverse cycle

    Power supply: 400V


    Inquiry Us





    Related Products

    Low Ambient Mini Splits

    Low Ambient Mini Splits

    Commercial Heat Pump

    Commercial Heat Pump

    70kW Air Source Heat Pump

    70kW Air Source Heat Pump

    Hot Tub Heat Pump

    Hot Tub Heat Pump

    Swimming Pool Heating and Cooling System

    Swimming Pool Heating and Cooling System

    Industrial Heat Pump

    Industrial Heat Pump

    Product Categories

    • High Temperature Heat Pumps
    • Air Source Heat Pumps
      • Domestic Heat Pumps
      • Commercial Heat Pumps
      • Industrial Heat Pumps
    • Swimming Pool Heat Pump
      • Residential Swimming Pool Heat Pump
      • Commercial Swimming Pool Heat Pump
      • Spa Heat Pump
    • Hot Water Heat Pumps
      • Domestic Hot Water Heat Pumps
      • Commercial Hot Water Heat Pumps
    • Cold Climate Heat Pumps
      • Low Temperature Heat Pumps
      • EVI Heat Pumps
    • Air to Water Heat Pumps
    • Geothermal Heat Pump
      • Ground Source Heat Pump
    • DC Inverter Heat Pumps
    • Underfloor Heating Heat Pumps
    • Heat Pump Cylinders
    • CO2 Heat Pumps
      • R744 Heat Pumps

    tyler@lnashp.com

    +86 15603721115

    +86 15603721115

    Cihu Technical Area, Maanshan. China

    Latest Post

  • How do I Reset an Air Source Heat Pump?
    How do I Reset an Air Source Heat Pump?
    2026-07-04
  • Air Source Heat Pump Keeps Tripping the Breaker
    Air Source Heat Pump Keeps Tripping the
    2026-06-27
  • Air Source Heat Pump Annual Service Cost
    Air Source Heat Pump Annual Service Cost
    2026-06-25
  • LatestPost

    • How do I Reset an Air Source Heat Pump?
      How do I Reset an Air Source Heat Pump?
      2026-07-04
    • Air Source Heat Pump Keeps Tripping the Breaker
      Air Source Heat Pump Keeps Tripping the
      2026-06-27
    • Air Source Heat Pump Annual Service Cost
      Air Source Heat Pump Annual Service Cost
      2026-06-25

    Feedback

    Contact Us

    tyler@lnashp.com

    +86 15603721115

    +86 15603721115

    Cihu Technical Area, Maanshan. China

    MOBILE WEBSITE

    Copyright © 2015 Maanshan Leomon Energy-Saving Technology Co. LTD All Rights Reserved.

    • Skype.
    • E-mail
    • Whatsapp
    • Inquiry
    Inquiry Us Now !
    Inquiry Us Now !