+86 15603721115 tyler@lnashp.com

Leomon
  • Home
  • About us
  • Products
    • High Temperature Heat Pumps
    • Air Source Heat Pumps
      • Domestic Heat Pumps
      • Commercial Heat Pumps
      • Industrial Heat Pumps
    • Swimming Pool Heat Pump
      • Residential Swimming Pool Heat Pump
      • Commercial Swimming Pool Heat Pump
      • Spa Heat Pump
    • Hot Water Heat Pumps
      • Domestic Hot Water Heat Pumps
      • Commercial Hot Water Heat Pumps
    • Cold Climate Heat Pumps
      • Low Temperature Heat Pumps
      • EVI Heat Pumps
    • Air to Water Heat Pumps
    • Geothermal Heat Pump
      • Ground Source Heat Pump
    • DC Inverter Heat Pumps
    • Underfloor Heating Heat Pumps
    • Heat Pump Cylinders
    • CO2 Heat Pumps
      • R744 Heat Pumps
  • News
  • Contact us
  1. Home
  2. Products
  3. CO2 Heat Pumps
  4. 75kW CO2 Heat Pump
  • 75kW CO2 Heat Pump

75kW CO2 Heat Pump

  • Product Item:CO2 Heat Pump
  • Max. COP: 5.56
  • Compressor : DC Inverter Compressor
  • Running Temp: -25℃~45℃
  • Function : Water Heating & Cooling
  • 75kW CO2 Heat Pump
    Inquiry Send Email

    Description

    This CO2 heat pump functions the same as a heat pump using conventional refrigerants. By using carbon dioxide as a refrigerant, heat pumps can operate more efficiently in high temperature ranges and operate more efficiently in low ambient temperatures. With a maximum outlet temperature of 90°C, CO2 heat pumps can be used to produce domestic hot water.


    CO2 heat pumps combined with buffer tanks can also be used to replace existing gas boilers for space heating. Existing central heating installations typically require a minimum supply temperature of 80°C. Therefore, CO2 heat pumps are an excellent device for making existing buildings more sustainable.


    CO2 heat pumps are suitable for collective heating in apartment buildings, small district heating systems, swimming pools, sports accommodation, sanitary hot water production in hotels and holiday parks. By combining the central heating system with hot water production, the seasonal coefficient of performance (SPF) becomes better.


    Specifications:

    Power supply 380V/3N/50Hz

    Heating Method Direct heating / circulating

    Maximum power input 18,600 W

    Refrigerant code R744(CO2)

    Noise level ≤ 67 db(A)

    Maximum flow 3.2(A)

    Water pipe interface size DN20

    Applicable ambient temperature -25~+43 ℃

    Casing material Hot-dip galvanized sheet metal plate Finishing powder coating

    Colour Dark grey (RAL7043)

    Weight 860(kg)

    Dimensions 2050*1150*1950

    Inquiry Us





    Related Products

    130kW Air Source Heat Pump for Heating & Cooling

    130kW Air Source Heat Pump for Heating & Cooling

    Residential Spa Heat Pumps

    Residential Spa Heat Pumps

    Industrial Air Source 95°C Hot Water Heat Pump

    Industrial Air Source 95°C Hot Water Heat Pump

    120°C Water-Source High-Temperature Heat Pump

    120°C Water-Source High-Temperature Heat Pump

    110kW High Temperature Heat Pump 75 Degrees

    110kW High Temperature Heat Pump 75 Degrees

    Air Conditioner Heat Pump Chiller Pool

    Air Conditioner Heat Pump Chiller Pool

    Product Categories

    • High Temperature Heat Pumps
    • Air Source Heat Pumps
      • Domestic Heat Pumps
      • Commercial Heat Pumps
      • Industrial Heat Pumps
    • Swimming Pool Heat Pump
      • Residential Swimming Pool Heat Pump
      • Commercial Swimming Pool Heat Pump
      • Spa Heat Pump
    • Hot Water Heat Pumps
      • Domestic Hot Water Heat Pumps
      • Commercial Hot Water Heat Pumps
    • Cold Climate Heat Pumps
      • Low Temperature Heat Pumps
      • EVI Heat Pumps
    • Air to Water Heat Pumps
    • Geothermal Heat Pump
      • Ground Source Heat Pump
    • DC Inverter Heat Pumps
    • Underfloor Heating Heat Pumps
    • Heat Pump Cylinders
    • CO2 Heat Pumps
      • R744 Heat Pumps

    tyler@lnashp.com

    +86 15603721115

    +86 15603721115

    Cihu Technical Area, Maanshan. China

    Latest Post

  • What Temperature Should You Set an Air Source Heat Pump to for Heating?
    What Temperature Should You Set an Air S
    2026-11-28
  • Are Low Pressures Normal in Air Source Heat Pumps?
    Are Low Pressures Normal in Air Source H
    2026-11-21
  • Are Air Source Heat Pumps Electric?
    Are Air Source Heat Pumps Electric?
    2026-11-14
  • LatestPost

    • What Temperature Should You Set an Air Source Heat Pump to for Heating?
      What Temperature Should You Set an Air S
      2026-11-28
    • Are Low Pressures Normal in Air Source Heat Pumps?
      Are Low Pressures Normal in Air Source H
      2026-11-21
    • Are Air Source Heat Pumps Electric?
      Are Air Source Heat Pumps Electric?
      2026-11-14

    Feedback

    Contact Us

    tyler@lnashp.com

    +86 15603721115

    +86 15603721115

    Cihu Technical Area, Maanshan. China

    MOBILE WEBSITE

    Copyright © 2015 Maanshan Leomon Energy-Saving Technology Co. LTD All Rights Reserved.

    • Skype.
    • E-mail
    • Whatsapp
    • Inquiry
    Inquiry Us Now !
    Inquiry Us Now !