+86 15603721115 tyler@lnashp.com

Leomon
  • Home
  • About us
  • Products
    • High Temperature Heat Pumps
    • Air Source Heat Pumps
      • Domestic Heat Pumps
      • Commercial Heat Pumps
      • Industrial Heat Pumps
    • Swimming Pool Heat Pump
      • Residential Swimming Pool Heat Pump
      • Commercial Swimming Pool Heat Pump
      • Spa Heat Pump
    • Hot Water Heat Pumps
      • Domestic Hot Water Heat Pumps
      • Commercial Hot Water Heat Pumps
    • Cold Climate Heat Pumps
      • Low Temperature Heat Pumps
      • EVI Heat Pumps
    • Air to Water Heat Pumps
    • Geothermal Heat Pump
      • Ground Source Heat Pump
    • DC Inverter Heat Pumps
    • Underfloor Heating Heat Pumps
    • Heat Pump Cylinders
    • CO2 Heat Pumps
      • R744 Heat Pumps
  • News
  • Contact us

News

  1. Home
  2. News
  3. What Temperature Should You Set an Air S...

What Temperature Should You Set an Air Source Heat Pump to for Heating?

To achieve optimal energy efficiency and comfort, the settings for an air source heat pump (ASHP) depend on two primary factors: the indoor thermostat setting and the system’s water supply temperature.

Below is a guide for setting your air source heat pump for heating, based on current industry best practices.

1. Indoor Thermostat Setting: Keep It Constant

1) Ideal Temperature: When you are at home during the day, it is recommended to set your thermostat to 20°C (68°F). You may also adjust it within the range of 18°C–21°C (64°F–70°F) based on your personal comfort preferences.
2) The Golden Rule: Avoid large temperature drops. Unlike traditional gas boilers or furnaces—which can generate high levels of heat very quickly—heat pumps are designed to operate steadily over longer periods.
3) It is strongly recommended to maintain a constant temperature, even at night or when you are away during the day. Attempting to "recover" the room temperature after a significant drop forces the heat pump to work under an excessive load. This often triggers the less efficient electric auxiliary heating (also known as "emergency heat" mode), leading to a sharp increase in your energy bills.

2. Water Supply Temperature Setting
"Water supply temperature" refers to the temperature of the hot water that the heat pump delivers to your heating emitters (such as radiators or underfloor heating pipes). Lowering the water supply temperature can significantly improve energy efficiency. As a rule of thumb, for every 1°C (1.8°F) increase in the water supply temperature, electricity consumption rises by approximately 2%–2.5%.

1) Underfloor Heating Systems: It is recommended to set the water supply temperature between 30°C and 35°C (86°F–95°F). Because underfloor heating systems have a very large surface area for heat emission, they can effectively heat a space even with a very low water supply temperature. 


2) Modern or large-sized radiators: It is recommended to set the water supply temperature between 40°C and 45°C (104°F–113°F). For radiator-based heating systems, this range represents the "sweet spot" for heat pump operating efficiency.


3) Older or undersized radiators: You may need to increase the water supply temperature to 50°C–55°C (122°F–131°F) to ensure adequate indoor heating. While this approach works, it reduces the heat pump’s Coefficient of Performance (COP) and increases operating costs.

3. Enable "Weather Compensation" (if available)
Rather than maintaining a fixed water supply temperature throughout the winter, using "weather compensation" (also known as a "heating curve") is the most efficient control strategy.

1) This feature automatically adjusts the water supply temperature based on the outdoor temperature.

2) On a mild autumn day (e.g., when the outdoor temperature is 10°C / 50°F), the system might only need to supply 35°C water to the radiators; during the depths of winter, it will automatically raise the supply temperature to 45°C or 50°C to maintain indoor comfort.

4. Domestic Hot Water Settings
If your heat pump system also provides domestic hot water via a storage tank (hot water cylinder):

1) It is recommended to set the daily hot water storage temperature to 50°C (122°F).

2) Ensure the system is configured to run a "legionella cycle" automatically once a week—briefly raising the water temperature to 60°C (140°F) to effectively kill bacteria. Keeping the water temperature at 60°C continuously would not only waste energy but also reduce the heat pump's operating efficiency. 


5. Managing Backup Systems / Dual-Fuel Systems

If you are using a hybrid energy system (e.g., a heat pump combined with an existing gas or electric furnace):

1) Set the thermostat for the backup furnace at least 5°F (approx. 3°C) lower than the setting for the heat pump. This ensures that the highly efficient heat pump handles the vast majority of the heating load, with the backup furnace activating only during periods of extreme cold.

2) Always set the system mode to "Heat" rather than "Auto" to prevent the system from accidentally switching to cooling mode on a sunny winter afternoon.

Checklist for Maximum Energy Efficiency:
1. Set your indoor thermostat to 68°F (20°C) and maintain this setting.
2. Set the water supply temperature for radiators to 40°C–45°C (or 30°C–35°C for underfloor heating systems).
3. Enable the "weather compensation" feature, which allows the system to automatically adjust based on outdoor environmental conditions.
4. Keep air filters clean and ensure the area around the outdoor unit is free of snow, fallen leaves, or debris to maintain proper airflow.

* Note: If the indoor space fails to reach the desired temperature using the recommended water supply temperatures, it may indicate that the radiator capacity is insufficient, or that the system requires professional adjustment and balancing.

Related News

The History and Evolution of Air Source Heat Pumps

The History and Evolution of Air Source Heat Pumps

Air Source Heat Pump Keeps Tripping the Breaker

Air Source Heat Pump Keeps Tripping the Breaker

Benefits of Repairing Air Source Heat Pumps

Benefits of Repairing Air Source Heat Pumps

What are the Basic Maintenance Tasks for An Air Source Heat Pump?

What are the Basic Maintenance Tasks for An Air Source Heat

What are the Key Factors Affecting the Lifespan of An Air Source Heat Pump?

What are the Key Factors Affecting the Lifespan of An Air So

Do Air Source Heat Pumps Need Servicing?

Do Air Source Heat Pumps Need Servicing?

Product Categories

  • High Temperature Heat Pumps
  • Air Source Heat Pumps
    • Domestic Heat Pumps
    • Commercial Heat Pumps
    • Industrial Heat Pumps
  • Swimming Pool Heat Pump
    • Residential Swimming Pool Heat Pump
    • Commercial Swimming Pool Heat Pump
    • Spa Heat Pump
  • Hot Water Heat Pumps
    • Domestic Hot Water Heat Pumps
    • Commercial Hot Water Heat Pumps
  • Cold Climate Heat Pumps
    • Low Temperature Heat Pumps
    • EVI Heat Pumps
  • Air to Water Heat Pumps
  • Geothermal Heat Pump
    • Ground Source Heat Pump
  • DC Inverter Heat Pumps
  • Underfloor Heating Heat Pumps
  • Heat Pump Cylinders
  • CO2 Heat Pumps
    • R744 Heat Pumps

tyler@lnashp.com

+86 15603721115

+86 15603721115

Cihu Technical Area, Maanshan. China

Latest Post

  • What Temperature Should You Set an Air Source Heat Pump to for Heating?
    What Temperature Should You Set an Air S
    2026-11-28
  • Are Low Pressures Normal in Air Source Heat Pumps?
    Are Low Pressures Normal in Air Source H
    2026-11-21
  • Are Air Source Heat Pumps Electric?
    Are Air Source Heat Pumps Electric?
    2026-11-14
  • LatestPost

    • What Temperature Should You Set an Air Source Heat Pump to for Heating?
      What Temperature Should You Set an Air S
      2026-11-28
    • Are Low Pressures Normal in Air Source Heat Pumps?
      Are Low Pressures Normal in Air Source H
      2026-11-21
    • Are Air Source Heat Pumps Electric?
      Are Air Source Heat Pumps Electric?
      2026-11-14

    Feedback

    Contact Us

    tyler@lnashp.com

    +86 15603721115

    +86 15603721115

    Cihu Technical Area, Maanshan. China

    MOBILE WEBSITE

    Copyright © 2015 Maanshan Leomon Energy-Saving Technology Co. LTD All Rights Reserved.

    • Skype.
    • E-mail
    • Whatsapp
    • Inquiry
    Inquiry Us Now !
    Inquiry Us Now !