+86 15603721115 tyler@lnashp.com

  • Home
  • About us
  • Products
    • CO2 Heat Pumps
      • R744 Heat Pumps
    • High Temperature Heat Pumps
    • Air Source Heat Pumps
      • Domestic Heat Pumps
      • Commercial Heat Pumps
      • Industrial Heat Pumps
    • Swimming Pool Heat Pump
      • Residential Swimming Pool Heat Pump
      • Commercial Swimming Pool Heat Pump
      • Spa Heat Pump
    • Hot Water Heat Pumps
      • Domestic Hot Water Heat Pumps
      • Commercial Hot Water Heat Pumps
    • Cold Climate Heat Pumps
      • Low Temperature Heat Pumps
      • EVI Heat Pumps
    • Air to Water Heat Pumps
    • Geothermal Heat Pump
      • Ground Source Heat Pump
    • DC Inverter Heat Pumps
    • Underfloor Heating Heat Pumps
    • Heat Pump Cylinders
  • News
  • Contact us

News

  1. Home
  2. News
  3. What is the Size of a 20HP Air Source He...

What is the Size of a 20HP Air Source Heat Pump?

A 20HP air source heat pump is an energy-efficient heating device, and its size and performance parameters vary depending on the brand and model. The common 20HP air source heat pump hot water unit has an overall size of about 1900mm (length) × 1100mm (width) × 2000mm (height) and a weight of 630kg. This large-scale equipment usually consists of multiple independent systems, equipped with key components such as fully enclosed scroll compressors and high-efficiency heat exchangers to ensure stable operation under various climatic conditions.

 

A 20HP air source heat pump has a high heating capacity and can usually meet the hot water needs of large-area buildings. For example, according to relevant calculations, a 20HP air source heat pump can cover a heating area of more than about 200 square meters.

 

When choosing an air source heat pump, in addition to considering its size and heating capacity, you also need to pay attention to its electrical parameters such as input power, current, and voltage. For example, the input power of Leomon 20HP air source heat pump is 19.5 kW and the current is 35.2 amps. It is recommended to use 16 square millimeter copper wire and 80 amp circuit breaker to ensure the safety of power supply. In addition, the noise level of the equipment is also an important consideration. The noise level of Finney 20HP heat pump is as low as 56 decibels, which is relatively quiet.

Related News

Is Air Source Heat Pump an IQ Tax?

Is Air Source Heat Pump an IQ Tax?

Differences between Direct-heating Air Source Heat Pump and Circulating Air Source Heat Pump

Differences between Direct-heating Air Source Heat Pump and

Is Air Source Heat Pump Heating Reliable?

Is Air Source Heat Pump Heating Reliable?

Wall-mounted Boiler vs. Air Source Heat Pump

Wall-mounted Boiler vs. Air Source Heat Pump

How much does it Cost to Heat a 150-square-meter House with an Air Source Heat Pump?

How much does it Cost to Heat a 150-square-meter House with

What is the Maximum Temperature of an Air Source Heat Pump?

What is the Maximum Temperature of an Air Source Heat Pump?

Product Categories

  • CO2 Heat Pumps
    • R744 Heat Pumps
  • High Temperature Heat Pumps
  • Air Source Heat Pumps
    • Domestic Heat Pumps
    • Commercial Heat Pumps
    • Industrial Heat Pumps
  • Swimming Pool Heat Pump
    • Residential Swimming Pool Heat Pump
    • Commercial Swimming Pool Heat Pump
    • Spa Heat Pump
  • Hot Water Heat Pumps
    • Domestic Hot Water Heat Pumps
    • Commercial Hot Water Heat Pumps
  • Cold Climate Heat Pumps
    • Low Temperature Heat Pumps
    • EVI Heat Pumps
  • Air to Water Heat Pumps
  • Geothermal Heat Pump
    • Ground Source Heat Pump
  • DC Inverter Heat Pumps
  • Underfloor Heating Heat Pumps
  • Heat Pump Cylinders

tyler@lnashp.com

+86 15603721115

+86 15603721115

Cihu Technical Area, Maanshan. China

Latest Post

  • How to Deal with the Noise of Modular Air Source Heat Pump?
    How to Deal with the Noise of Modular Ai
    2025-10-18
  • What should I do if an Air Source Heat Pump Displays an F3 fault?
    What should I do if an Air Source Heat P
    2025-10-11
  • How many HP Air Source Heat Pumps should be Installed for a 2400 Square Meter Heating Area?
    How many HP Air Source Heat Pumps should
    2025-10-04
  • LatestPost

    • How to Deal with the Noise of Modular Air Source Heat Pump?
      How to Deal with the Noise of Modular Ai
      2025-10-18
    • What should I do if an Air Source Heat Pump Displays an F3 fault?
      What should I do if an Air Source Heat P
      2025-10-11
    • How many HP Air Source Heat Pumps should be Installed for a 2400 Square Meter Heating Area?
      How many HP Air Source Heat Pumps should
      2025-10-04

    Feedback

    Contact Us

    tyler@lnashp.com

    +86 15603721115

    +86 15603721115

    Cihu Technical Area, Maanshan. China

    MOBILE WEBSITE

    Copyright © 2015 Maanshan Leomon Energy-Saving Technology Co. LTD All Rights Reserved.

    • Skype.
    • E-mail
    • Whatsapp
    • Inquiry
    Inquiry Us Now !
    Inquiry Us Now !